Difference between revisions of "LECO method in estimating richness"

From AAPG Wiki
Jump to navigation Jump to search
m (FWhitehurst moved page Using the LECO method to estimate richness to LECO methodin estimating richness: most important term first)
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Merge|Using conventional well logs to estimate richness}}
 
{{publication  
 
{{publication  
 
  | image  = exploring-for-oil-and-gas-traps.png
 
  | image  = exploring-for-oil-and-gas-traps.png
Line 6: Line 7:
 
  | part    = Critical elements of the petroleum system
 
  | part    = Critical elements of the petroleum system
 
  | chapter = Evaluating source rocks
 
  | chapter = Evaluating source rocks
  | frompg  = 6-1
+
  | frompg  = 6-12
  | topg    = 6-41
+
  | topg    = 6-12
 
  | author  = Carol A. Law
 
  | author  = Carol A. Law
 
  | link    = http://archives.datapages.com/data/specpubs/beaumont/ch06/ch06.htm
 
  | link    = http://archives.datapages.com/data/specpubs/beaumont/ch06/ch06.htm
Line 16: Line 17:
 
==Definition of LECO method==
 
==Definition of LECO method==
  
The LECO method of estimating total organic carbon (TOC) uses an instrument known as a LECO carbon analyzer to measure TOC values by combusting the organic carbon and measuring the resulting carbon dioxide produced. The LECO method has almost totally been replaced by Rock-Eval pyrolysis. However, data may still be available from prior analysis.
+
The LECO method of estimating [[total organic carbon (TOC)]] uses an instrument known as a LECO carbon analyzer to measure TOC values by combusting the organic carbon and measuring the resulting carbon dioxide produced. The LECO method has almost totally been replaced by [[Rock-Eval pyrolysis]]. However, data may still be available from prior analysis.
  
 
==Measuring TOC with LECO==
 
==Measuring TOC with LECO==
Line 24: Line 25:
  
 
==Comparing TOC values==
 
==Comparing TOC values==
The TOC measured by the LECO method does not include a measurement of the free hydrocarbons present in the sample. The free hydrocarbons would be volatized when samples are dried after acid treatment is performed to remove the inorganic carbonate minerals. Thus, if a sample has a high free hydrocarbon content, the LECO TOC value will be smaller than a Rock-Eval TOC value, which includes free hydrocarbons (S<sub>1</sub>) in the TOC calculation.
+
The TOC measured by the LECO method does not include a measurement of the free hydrocarbons present in the sample. The free hydrocarbons would be volatized when samples are dried after acid treatment is performed to remove the inorganic carbonate minerals. Thus, if a sample has a high free hydrocarbon content, the LECO TOC value will be smaller than a Rock-Eval TOC value, which includes free hydrocarbons (S1) in the TOC calculation.
  
 
==See also==
 
==See also==
 
* [[Source rock richness]]
 
* [[Source rock richness]]
* [[Measuring a rock's ability to generate hydrocarbons]]
+
* [[Rock-Eval pyrolysis]]
* [[Using pyrolysis to estimate richness]]
 
 
* [[Using conventional well logs to estimate richness]]
 
* [[Using conventional well logs to estimate richness]]
  
Line 39: Line 39:
 
[[Category:Critical elements of the petroleum system]]  
 
[[Category:Critical elements of the petroleum system]]  
 
[[Category:Evaluating source rocks]]
 
[[Category:Evaluating source rocks]]
 +
[[Category:Treatise Handbook 3]]

Latest revision as of 15:49, 9 February 2022

Exploring for Oil and Gas Traps
Series Treatise in Petroleum Geology
Part Critical elements of the petroleum system
Chapter Evaluating source rocks
Author Carol A. Law
Link Web page
Store AAPG Store

Definition of LECO method

The LECO method of estimating total organic carbon (TOC) uses an instrument known as a LECO carbon analyzer to measure TOC values by combusting the organic carbon and measuring the resulting carbon dioxide produced. The LECO method has almost totally been replaced by Rock-Eval pyrolysis. However, data may still be available from prior analysis.

Measuring TOC with LECO

Samples are powdered, weighed, and chemically treated prior to analysis to remove the inorganic carbon (carbonate) from the rock. The sample is then combusted in the presence of excess oxygen, allowing carbon dioxide to form from the free (organic) carbon in the rock.

The amount of carbon dioxide is directly proportional to the amount of organic carbon or the TOC of the rock. However, the TOC value can be inflated due to the presence of sulfur compounds, water, and carbonate if they have not been removed prior to analysis.

Comparing TOC values

The TOC measured by the LECO method does not include a measurement of the free hydrocarbons present in the sample. The free hydrocarbons would be volatized when samples are dried after acid treatment is performed to remove the inorganic carbonate minerals. Thus, if a sample has a high free hydrocarbon content, the LECO TOC value will be smaller than a Rock-Eval TOC value, which includes free hydrocarbons (S1) in the TOC calculation.

See also

External links

find literature about
LECO method in estimating richness
Datapages button.png GeoScienceWorld button.png OnePetro button.png Google button.png