Search results

Jump to navigation Jump to search
Results 1 – 21 of 69
Advanced search

Search in namespaces:

  
  
  
  
  
  
  
  
  
  
  • * [http://www.searchanddiscovery.com/documents/nanz/images/23.htm Gamma-ray and resistivity response]
    419 bytes (57 words) - 15:36, 6 January 2015
  • ==Outcrop gamma-ray logging==
    3 KB (412 words) - 22:40, 1 February 2022
  • ...P_{\text{c system2}} \left ( \frac{\gamma \cos \Theta \text{ of system1}}{\gamma \cos \Theta \text{ of system2}} \right )</math> ...c res}} = P_{\text{c lab}} \left ( \frac{\gamma \cos \Theta_{\text{res}}}{\gamma \cos \Theta_{\text{lab}}} \right )</math>
    6 KB (850 words) - 17:22, 4 April 2022
  • | rowspan = 2 | Correlation || [[Basic open hole tools#Gamma ray|Gamma ray]] | Spectral gamma ray
    10 KB (1,427 words) - 16:26, 18 January 2022
  • ...open hole tools#Resistivity|electric]], [[Basic open hole tools#Gamma ray|gamma ray]], etc.). It is important to realize that a sonic log never goes to the
    2 KB (348 words) - 19:10, 27 January 2022
  • ...e measured using density sonic, neutron, [[Basic open hole tools#Gamma ray|gamma ray]], and [[Basic open hole tools#Resistivity|resistivity logs]]. The tabl | Gamma ray (GR) or uranium (U) || High || High GR caused by U; can be linear with
    5 KB (768 words) - 15:48, 9 February 2022
  • ...nts. (right) Density values measured by the BHGM (left line) and the gamma-gamma tools (right line). Copyright: Rasmussen;<ref name=Rasmussen>Rasmussen, N. ...w is caused by a remote higher [[porosity]] zone not detected by the gamma-gamma density log. The broader difference anomaly observed over the length of the
    11 KB (1,596 words) - 18:08, 24 January 2022
  • :<math>(\rho_{\rm w} - \rho_{\rm h}) \mbox{g} h = \frac{2\gamma \cos \theta}R</math> :<math>h = \frac{\left(\displaystyle\frac{2\gamma \cos \theta} R \right)}{(\rho_{\rm w} - \rho_{\rm h})\mbox{g}}</math>
    3 KB (488 words) - 16:13, 31 March 2022
  • | [[Basic open hole tools#Gamma ray|Gamma ray]] || 6 || 20 || √ || √ || √ || √ || √ || √ || – || – || | Spectral [[Basic open hole tools#Gamma Ray|GR]] || 6 || 20 || √ || √ || √ || NR || √ || √ || NR || – |
    5 KB (544 words) - 16:27, 18 January 2022
  • ...can include standard measurements of the formation (electric logs such as gamma ray, resistivity, or porosity), drilling parameters (e.g., downhole torque,
    2 KB (206 words) - 21:17, 3 December 2015
  • ...while drilling (MWD) technology provides downhole evaluation of formation gamma ray, resistivity, and [[porosity]] while drilling is in progress. Mechanica ...servoir evaluation in the past 10 years. [[Basic open hole tools#Gammy ray|Gamma ray]], resistivity, and porosity logs obtained during drilling are commonly
    8 KB (1,083 words) - 21:18, 19 January 2022
  • ...y between 6330 and 6370 ft is caused by porosity not detected by the gamma-gamma [[density log]]. The broader difference anomaly observed over the length of ...r poor volume sampling. However, the broad departure of the BHGM and gamma-gamma logs over the depth range of the logged section is typical of a structural
    10 KB (1,517 words) - 15:54, 20 January 2022
  • | Gamma Ray (GR) || Lithology interpretation, shale volume calculation, calculate c [[File:Well_Log_Analysis_Fig-3.png|thumb|300px|Figure 3-The use of gamma ray log to determine the lithology.<ref>Railsback, 2011, Characteristics of
    25 KB (3,679 words) - 21:17, 13 March 2019
  • | Gamma-gamma log || 8 || 20 || 17 || 0.5
    5 KB (720 words) - 18:07, 24 January 2022
  • :<math>\mbox{P}_{\rm c} = \frac{2\gamma \cos \Theta}{\mbox{r}}</math> :<math>\mbox{r} = \frac{2\gamma \cos \Theta}{\mbox{P}_{\rm c}}</math>
    6 KB (898 words) - 16:21, 4 April 2022
  • | Gamma ray ...ces make use of three different physical phenomena: spontaneous potential, gamma rays, and photoelectric effect. Table 2 shows the resolution and applicatio
    23 KB (3,350 words) - 17:26, 18 January 2022
  • ...wise to select the gamma ray from the induction tool as the base log. The gamma ray from the density curve and all curves recorded with the density are the :A core gamma ray can be a valuable aid in establishing depth correlations between core a
    13 KB (2,094 words) - 17:42, 18 January 2022
  • ...source, counts the number of returning gamma rays. The number of returning gamma rays is an indicator of formation bulk density. The litho-density tool (LDT
    12 KB (1,763 words) - 16:18, 5 April 2022
  • * [[Basic open hole tools#Gamma ray|Gamma ray]] ==Gamma ray logs==
    25 KB (3,637 words) - 19:39, 18 January 2022
  • ...otential (SP)]]. The most common methods for estimating shale volumes from gamma ray and SP logs are outlined here. Other measurements can be used under spe ===Shale volume from gamma ray===
    25 KB (3,776 words) - 19:53, 18 January 2022

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)