Line 113: |
Line 113: |
| {| class = "wikitable" | | {| class = "wikitable" |
| |- | | |- |
− | ! Step | + | ! Step || Action |
− | ! Action
| |
| |- | | |- |
− | | 1 | + | | 1 || Inspect the tool and check calibration before going in the hole. |
− | | Inspect the tool and check calibration before going in the hole. | |
| |- | | |- |
− | | 2 | + | | 2 || Run quartz and strain gauges simultaneously. Record both readings independently. Normalize to one another after completing the survey. |
− | | Run quartz and strain gauges simultaneously. Record both readings independently. Normalize to one another after completing the survey. | |
| |- | | |- |
− | | 3 | + | | 3 || Maintain a slight overflow of mud to keep the level in the borehole constant during the survey and to prevent mud hydrostatic pressure errors. |
− | | Maintain a slight overflow of mud to keep the level in the borehole constant during the survey and to prevent mud hydrostatic pressure errors. | |
| |- | | |- |
− | | 4 | + | | 4 || Take mud hydrostatic pressures while descending into the hole to give the instruments time to equilibrate to changing temperature and pressure and to provide a mud hydrostatic pressure profile. |
− | | Take mud hydrostatic pressures while descending into the hole to give the instruments time to equilibrate to changing temperature and pressure and to provide a mud hydrostatic pressure profile. | |
| |- | | |- |
− | | 5 | + | | 5 || Check for tool errors by calculating mud hydrostatic pressures at different depths from mud weight; check them against measured mud hydrostatic pressures at the same depths. |
− | | Check for tool errors by calculating mud hydrostatic pressures at different depths from mud weight; check them against measured mud hydrostatic pressures at the same depths. | |
| |} | | |} |
| | | |