|+ {{table number|2}}Resolutions and limitations of cased hole logging devices
 
|+ {{table number|2}}Resolutions and limitations of cased hole logging devices
 
|-
 
|-
! Tool
+
! Tool || Vertical Resolution || Radius of Investigation || Applications || Limitations
! Vertical Resolution
  −
! Radius of Investigation
  −
! Applications
  −
! Limitations
   
|-
 
|-
| Gamma ray
+
| Gamma ray || [[length::2 ft]] || [[length::12 in]] || Well-to-well correlation and estimates ''V''<sub>sh</sub> || Affected by radioactive scale near perforations
| [[length::2 ft]]
  −
| [[length::12 in]]
  −
| Well-to-well correlation and estimates ''V''<sub>sh</sub>
  −
| Affected by radioactive scale near perforations
   
|-
 
|-
| Spectral gamma ray
+
| Spectral gamma ray || [[length::3 ft]] || [[length::16 in]] || Well-to-well correlation and estimates ''V''<sub>sh</sub> || —
| [[length::3 ft]]
  −
| [[length::16 in]]
  −
| Well-to-well correlation and estimates ''V''<sub>sh</sub>
  −
| —
   
|-
 
|-
| Pulsed neutron
+
| Pulsed neutron || [[length::2 ft]] || [[length::18 in]] || Determines water saturation and estimates porosity || Does not work in freshwater and severely underestimates porosity in the presence of gas
| [[length::2 ft]]
  −
| [[length::18 in]]
  −
| Determines water saturation and estimates porosity
  −
| Does not work in freshwater and severely underestimates porosity in the presence of gas
   
|-
 
|-
| Compensated neutron
+
| Compensated neutron || [[length::3 ft]] || [[length::10 in]] || Estimates porosity || Severely underestimates porosity in the presence of gas
| [[length::3 ft]]
  −
| [[length::10 in]]
  −
| Estimates porosity
  −
| Severely underestimates porosity in the presence of gas
   
|}
 
|}
  