Changes

Jump to navigation Jump to search
6 bytes added ,  13:01, 18 June 2014
Line 73: Line 73:  
Liquid and gas permeability can be determined on core samples in the laboratory. However, gas permeability is determined most frequently because sample preparation is simplified and the analytical procedure is fairly rapid. Two methods currently exist for gas permeability determination: steady-state and unsteady-state.
 
Liquid and gas permeability can be determined on core samples in the laboratory. However, gas permeability is determined most frequently because sample preparation is simplified and the analytical procedure is fairly rapid. Two methods currently exist for gas permeability determination: steady-state and unsteady-state.
   −
[[file:permeability_fig4.png|thumb|{{figure number|4}}Schematic diagram of (a) steady-state and (b) unsteady-state apparatus.]]
+
===Gas permeability by steady-state method===
   −
===Gas permeability by steady-state method===
+
[[file:permeability_fig4.png|thumb|300px|{{figure number|4}}Schematic diagram of (a) steady-state and (b) unsteady-state apparatus.]]
    
A simplified schematic diagram of the steady-state apparatus is shown in [[:file:permeability_fig4.png|Figure 4a]]. The apparatus includes a pressurized gas cylinder, a Hassler core holder, and a flowmeter. The apparatus is designed to ensure that no restrictions exist in flow lines that could cause a pressure drop between the core face and the pressure gauges. To determine air permeability, a clean, dried core sample is first placed in the core holder and pressure is applied to the rubber sleeve to seal it to the core. Air is then injected at a constant pressure until gas production rate and pressure stabilize. The pressure differential between the two ends of the core and flow rate are recorded for permeability calculation using the integrated form of Darcy's law for a compressible fluid. Thus,
 
A simplified schematic diagram of the steady-state apparatus is shown in [[:file:permeability_fig4.png|Figure 4a]]. The apparatus includes a pressurized gas cylinder, a Hassler core holder, and a flowmeter. The apparatus is designed to ensure that no restrictions exist in flow lines that could cause a pressure drop between the core face and the pressure gauges. To determine air permeability, a clean, dried core sample is first placed in the core holder and pressure is applied to the rubber sleeve to seal it to the core. Air is then injected at a constant pressure until gas production rate and pressure stabilize. The pressure differential between the two ends of the core and flow rate are recorded for permeability calculation using the integrated form of Darcy's law for a compressible fluid. Thus,

Navigation menu